DG-CLC-2023

VersaTherm ® QuickTherm ® Main Panels (VT-MP) Panel Size = 31-1/2 in. x 15-3/4 in. = (496) 3.44 ft 2 (10 panels per box) Use to calculate number of panels: x 0.233 = (Round Up) Project square footage Number of main panels needed EXAMPLE: 400 ft 2 x 0.233 = 93.2 or (94) panels. Use to calculate number of cases: ÷ 10 = (Round Up) Number of main panels needed Number of cases needed EXAMPLE: 94 panels ÷ 10 = 9.4 or (10) cases. Return Panels (VT-RP) Panel Size = 15-3/4 in. x 15-3/4 in. = (248) 1.72 ft 2 (20 panels per box) Use to calculate number of panels: x 0.117 = (Round Up) Project square footage Number of main panels needed EXAMPLE: 400 ft 2 x 0.117 = 46.8 or (47) panels. Use to calculate number of cases: ÷ 20 = (Round Up) Number of main panels needed Number of cases needed EXAMPLE: 47 panels ÷ 20 = 2.35 or (3) cases. Notes:The project square footage includes only the area of the room or project space that is to be covered by tubing. Do not include areas under cabinets or any areas that will not receive tubing. PROJECT DESIGN IS HIGHLY RECOMMENDEDWITH VERSATHERM. QT-100 (1”) Panel Size = 2’ x 4’ = 8 ft 2 (18 panels per bundle) QT-200 (2”) Panel Size = 2’ x 4’ = 8 ft 2 (10 panels per bundle) Use to calculate number of panels: Use to calculate number of bundles: ÷ (18 or 10) = (Round Up) Number of QT panels needed Number of bundles needed EXAMPLE: 438 panels ÷ 10 (QT 200) = 43.8 or (44) bundles. ÷ 8 = (Round Up) Project square footage Number of QT panels needed EXAMPLE: 3,500 ft 2 ÷ 8 = 437.5 or (438) panels. VersaTherm & QuickTherm Material Worksheet - Radiant Hydronic Systems VersaTherm & QuickThermMaterial Worksheet | 359 P: 800.752.2082 | # 14 13 12 11 10 9 8 7 5 4 3 1 6 2

RkJQdWJsaXNoZXIy OTA1MTgx